EWDR FAMILY

IWP 985 LX - IWK std

The IWP985LX power board has three analogue inputs
for NTC temperature probes (parameter selectable
PTC) and four digital relay outputs for control of the
compressor, defrosting, fans, alarm, or light output,
auxiliary output, ON-OFF. The value read by the probe
is displayed on the IWK standard (32x74) remote
keyboard with three digits plus the minus sign.
Reading with a decimal point is
parameter-programmable. The buzzer is optional. All
versions have a TTL connection so that the Copy Card
quick programming accessory can be used.
The IWP985LX power board is fitted with an RS-485
optoinsulated internal connection and can also be
connected to the TelevisSystem.
It has two voltage-free programmable digital inputs.
• The range also includes models that are able to
manage and store the alarms, in compliance with the
HACCP requirements.
The power supply is 230Va.